DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter

Product Details
Customization: Available
After-sales Service: Technical Support
Warranty: 1 Year
Still deciding? Get samples of US$ 1200/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
Customization from Designs
The supplier provides design based customization services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (20)
  • DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter
  • DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter
  • DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter
  • DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter
  • DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter
  • DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Model Selection
  • Certifications
Overview

Basic Info.

Model NO.
ATLQ
Main Application
Nature Gas, Gas
Size
DN50-100
Sensor
Tube/Flange
Application
Industrial Production
Type
Turbine Flow Meter
Measuring Media
Gas
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Caliber
DN25 - 250
Range Ratio
1:10, 1:20, 1:30
Temperature of Medium
-10~+100 Degree
Communication Signal
Three-Wire Pulsing
Transport Package
Carton Box with PP Film Wooden Box
Origin
China
HS Code
9026801000
Production Capacity
50000 PCS / Year

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 40.00cm
Package Gross Weight
10.000kg
Lead Time
15 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Product Description

Gas Lobed Rotor (Roots) Flowmeter widely used in urban gas trade measurement, especially for organs, schools, enterprises and institutions, hotels, restaurants and other large gas users trade measurement. It can also be used for various industrial raw gas main metering, gas distribution station, main gas supply station and other occasions.

DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter

Product Parameters
 
 
Model Flow Spec
Size
(mm)
Flow Range
(m³/h)
Start up flow
(m³/h)
Max Pressure loss
(KPa)
ATQL-25 G16 DN25 1-25 0.05 0.08
ATQL-40 G25 DN40 1-40 0.05 0.08
ATQL-50 G25
DN50
1-40 0.1 0.08
G40 2-65 0.1 0.1
G65 2-100 0.12 0.15
ATQL-80 G65
DN80
2-100 0.12 0.15
G100 2.5-160 0.1 0.15
G160 3-250 0.1 0.18
ATQL-100 G160 DN100 3-250 0.1 0.2
G250 4-500 0.65 0.35
ATQL-150 G400 DN150 8-650 0.76 0.46
G650 15-1000 0.85 0.5
ATQL-200 G1600 DN200 32-1600 0.95 0.6
Detailed Photos
DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow MeterDN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow MeterDN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter
Installation Instructions

DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter

Installation Tips
 

  1. Before installation and use, the user should read this description in detail to ensure the correct installation and reasonable use of the flow meter, so as not to affect the normal operation and measurement accuracy;
  2. Before installing the flow meter, the outlet package should be removed, and granular impurities must be prevented from falling into the measuring room, such as anti-rust oil on the surface of the measuring room, which can be washed with gasoline or kerosene, and impurities in the pipeline should be strictly removed. A filter or filter should be installed upstream of the flow meter to prevent rust slag, welding slag and impurities from entering the measuring room;
  3. When the flow meter is installed, whether the outlet is vertical or horizontal, the rotor axis should be kept horizontal as far as possible. In order to prevent the rust slag and welding slag impurities in the newly installed pipeline from entering the flow meter, the user should first install the transition pipe on the installation position of the flow meter, vent for a period of time (about a week), ensure that there are no large particles of impurities, and then replace the flow meter;
  4. Install the flow meter to ensure that the center of the flow meter is aligned with the center of the pipeline, without misalignment, and that the flow meter is not affected by external forces (including axial and tangential).
Model Selection
ATQL  Parameters ××× × × × × × ×
Size (mm) DN25-DN200mm              
Accuracy 1.5% (standard) 1
1.0% 2
Nominal Pressure 1.0MPa 1
1.6MPa 2
Others 3
Body Material Aluminum Alloy A
Stainless Steel S
Output/
Communication
Pulse 1
Pulse+4~20mA 3
Pulse+4~20mA+RS485 4
Power Supply Battery Powered 1
Battery Powered + External Power DC24V 2
Ex-proof With 1
Without 2
Installation Horizontal H
Vertical V
Certifications

DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter

DN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow MeterDN25-DN200 RS485 Pulse Ex-Proof 4-20mA Output Nature Gas Roots Flow Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier