CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter

Product Details
Customization: Available
After-sales Service: Technical Support
Warranty: 1 Year
Still deciding? Get samples of US$ 600/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
Customization from Designs
The supplier provides design based customization services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (20)
  • CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
  • CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
  • CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
  • CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
  • CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
  • CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
Find Similar Products
  • Overview
  • Product Description
  • Applications
  • Detailed Photos
  • Why Choose Us
  • Product Parameters
  • Installation Instructions
  • Model Selection
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
ATLD
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Size
DN3 - DN3000
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Caliber
DN3 - 3000
Signal Output Function
4-20mA/Pulse
Temperature of Medium
-20~+60deg C
Communication Signal
RS485(Standard), Hart(Optional),GPRS/GSM (Optiona
Nominal Pressure
0.6-1.6MPa
Power Supply
AC22V and DC24V
Transport Package
Carton Box with PP Film Wooden Box
Origin
China
HS Code
9026800000
Production Capacity
50000 PCS / Year

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 40.00cm
Package Gross Weight
10.000kg
Lead Time
15 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Product Description

CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter

Applications

Electromagnetic flow meter is widely used in water treatment, food industry, pharmaceutical, petrochemical, paper mill, chemical monitoring etc. 
In the metallurgical industry, it is often used to control the flow of cooling water for continuous steel casting, continuous steel rolling, and steel-making electric furnaces; 

In the field of water supply and drainage in public utilities, electromagnetic flow meters are often used for the transfer measurement of finished product water and raw water in water plants;

In the pulp process of the paper industry, electromagnetic flow meters are involved in the measurement of the flow of grinding pulp, water, acid, and alkali; 

In the coal industry, measuring coal washing and pipeline hydraulic conveying coal slurry;

As for food and beverage industries, it is used for beer and beverage filling measurement;

As for chemical and petrochemical industries, it is used to measure corrosive liquids, such as acids and alkalis etc.

Detailed Photos

CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow MeterCE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow MeterCE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
Why Choose Us
CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter
Product Parameters
Size DN3-DN3000mm
Nominal Pressure 0.6-1.6Mpa(2.5Mpa/4.0Mpa/6.4Mpa...Max 42Mpa)
Accuracy +/-0.5%(Standard)
+/-0.3% or +/-0.2%(Optional)
Liner PTFE, Neoprene, Hard Rubber, EPDM, FEP, Polyurethane, PFA
Electrode SUS316L, Hastelloy B, Hastelloy C
Titanium, Tantalum, Platinium-iridium
Structure Type Integral type, remote type, submersible type, ex-proof type
Medium Temperature -20~+60 degC(Integral type)
Remote type(Neoprene,Hard Rubber,Polyurethane,EPDM) -10~+80degC
Remote type(PTFE/PFA/FEP) -10~+160degC
Ambient Temperature -20~+60deg C
Ambient Humidity 5-100%RH(relative humidity)
Measuring Range Max 15m/s
Conductivity >5us/cm
Protection Class IP65(Standard); IP68(Optional for remote type)
Process Connection Flange (Standard), Wafer, Thread, Tri-clamp etc (Optional)
 
Output Signal 4-20mA/Pulse
Communication RS485(Standard), HART(Optional),GPRS/GSM (Optional)
Power Supply AC220V (can be used for AC85-250V)
DC24V (can be used for DC20-36V)
DC12V (optional), Battery Powered 3.6V (optional)
Power Consumption <20W
Alarm Upper Limit Alarm / Lower Limit Alarm
Self-diagnosis Empty Pipe Alarm, Exciting Alarm
Explosion Proof ATEX
Installation Instructions
 
CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter

In order to obtain a stable and accurate flow measurement, it is very important that the flow meter is installed correctly in the pipe system.
Do not install the meter near equipment that produces electrical interference such as electric motors, transformers, variable frequency, power cables etc.
Avoid locations with pipe vibrations for example pumps;

Do not install the meter close to pipeline valves, fittings or impediments which can cause flow disturbances;

Place the meter where there is enough access for installation and maintenance tasks.
Model Selection
ATLD xxx x x x x x x x x
Caliber DN3mm-DN3000mm                  
Nominal Pressure 0.6Mpa 1
1.0Mpa 2
1.6Mpa 3
4.0Mpa 4
Other 5
Connection Mode Flange connection 1
Clamp connection 2
Sanitary connection 3
Liner Material PTFE 1
PFA 2
Neoprenen 3
Polyurethane 4
Ceramic 5
Electrode Material 316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Platinum-iridium 5
Tantalum 6
Stainless steel covered with tungsten carbide 7
Structure Type Integral type 1
Remote type 2
Remote type immerse 3
Integral type Ex-proof 4
Remote type Ex-proof 5
Power 220VAC 50Hz E
24VDC G
Output communication Flow volume 4-20mADC/pulse A
Flow volume 4-20mADC/RS232C communication B
Flow volume 4-20mADC/RS485 communication C
Flow volume HART output/with communication D
Converter Figure Square A
Circular B
Packaging & Shipping

CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow MeterCE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow MeterCE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter

CE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow MeterCE Atex RS485 Modbus 4-20mA Hot Tap Insertion Electromagnetic Flow Meter

        Q: How long is your delivery time?
        A: it depends on the quantity. Normally it's about a week to two weeks.

        Q: How to get quotation?
        A: Please tell us the pipe diameter, measuring medium, flow rate, temperature, pressure, connection type and accuracy of the product you need, we will choose the most suitable product for you.

        Q:can i design our own logo or color ?
        A:sure ! we are glad to help you.

        Q:Can I place a small order for the first time?
        A:YES. This shows your recognition of us, I believe we will have longer-term cooperation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier