CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters

Product Details
Customization: Available
Accuracy: >±1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Still deciding? Get samples of US$ 400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
Customization from Designs
The supplier provides design based customization services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (20)
  • CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
  • CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
  • CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
  • CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
  • CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
  • CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Why Choose Us
  • Installation Instructions
  • Model Selection
  • Calibration
  • Certifications
Overview

Basic Info.

Model NO.
LUGB
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Caliber
DN15 - 300
Power Supply
DC12V or DC24V
Temperature of Medium
Typically -40 ~ 150 Degree
Material
Carbon Steel, Stainless Steel
Transport Package
Carton Box with PP Film Wooden Box
Origin
China
HS Code
9026801000
Production Capacity
50000 PCS / Year

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 40.00cm
Package Gross Weight
10.000kg
Lead Time
15 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Product Description

The company produced LUGB vortex flowmeter, there are remote transmission type, field display type, temperature and pressure automatic compensation type. Can be widely used in chemical, petroleum, metallurgy, light industry, environmental protection, municipal, electric power and other departments.
CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters

Product Parameters
Performance Technical parameter
Measuring medium Steam, compressed air, liquid (single phase media)
Medium temperature -40ºC~+350ºC
Medium pressure 1.6,2.5,4.0Mpa
Range ratio 1:8~1-30(air at reference scale) 1:8~1:40(Refer to normal temperature water)
Measuring range Liquid 0.4 ~ 0.7m/s Gas 4.0 ~ 60m/s Steam 5.0 ~ 70m/s
Specification DN25~DN300mm
Material 304, 316L a variety of materials
Reynolds number Normal 2 x 104Cd to 7 x 106
Drag coefficient Cd≤2.6
Vibration acceleration LUGB type≤0.2g
Class of protection IP65
Explosion-proof class (ia)   II CT6
Accuracy Level 1.0, level 1.5
Environmental condition Ambient temperature -40ºC~+55ºC(non-explosion-proof place) -20ºC~+55ºC(explosion-proof place)
Relative humidity ≤85%
Atmospheric pressure 86~106Kpa
Power supply Non-explosion-proof type Pulse type +12VDC 20mA
current type +24VDC 20mA
Output signal Frequency pulse signal 2 ~ 3000Hz Low level ≤1V High level ≥6V
Two-wire 4-20mA signal (isolated output) load ≤500Ω
Why Choose Us
CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
Installation Instructions
CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
  1. When using a vortex flowmeter to measure steam, the body and pipe must be insulated, the flange must be clamped, and there must be no air leakage, otherwise the instrument is easy to damage;
  2. It is better to install the instrument indoors, away from vibration and strong electromagnetic interference. If outdoors, the watch head can be protected;
  3. The instrument should have 10-15 times the straight pipe section, and then have more than 5 times the straight pipe section. Select the installation place to facilitate installation, wiring and debugging;
  4. For a straight pipe section, weld the two flanges before installation, then install the instrument and clamp it, cut off the equal length straight pipe, and then install the whole table welded before. Never weld the watch on the flange.
Model Selection
CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersSelection Directions:

1. Measuring medium: Vortex flowmeter is a speed flowmeter, its principle, determines its measuring medium type, can be liquid, can also be gas or steam;

2. Pipe diameter: Flange connected vortex flowmeter can be divided into pipe type and insert type installation according to the different installation methods;

3. Measurement accuracy: The accuracy of the flange connected vortex flowmeter also has several grades, and it is divided according to the measurement medium. If it is to measure liquid, the measurement accuracy can reach 1.0%, and if it is to measure gas, the accuracy can reach 1.5%. If it is inserted vortex flowmeter, the accuracy can reach level 1.5% and 2.5%;

4. Medium temperature: Generally speaking, it is divided into three ranges, which are divided into normal temperature, medium and high temperature;

5. Nominal pressure: mainly divided according to the installation method, the main demand on the market is as follows: for example, flange clamp type (2.5MPa), flange connection type (1.0/1.6/2.5MPa), plug-in installation type (1.6MPa/2.5MPa/4.0MPa);
Calibration
Critical Venturi Sonic Nozzle Calibration Device

CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
Certifications

CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters

CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters
CO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow MetersCO2 Hart Protocol Steam Pulse Output Max 350degc Steam Flue Gas Compressed Air Rotary Vortex Flow Meters        Q: How long is your delivery time?
        A: it depends on the quantity. Normally it's about a week to two weeks.

        Q: How to get quotation?
        A: Please tell us the pipe diameter, measuring medium, flow rate, temperature, pressure, connection type and accuracy of the product you need, we will choose the most suitable product for you.

        Q:can i design our own logo or color ?
        A:sure ! we are glad to help you.

        Q:Can I place a small order for the first time?
        A:YES. This shows your recognition of us, I believe we will have longer-term cooperation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier